A METHOD OF MEASURING THE RESISTIVITY OF COPPER FROM 298 TO 77 K.
Author(s) : ROSS K. A., KIM H. T.
Type of article: Article
Summary
THE RESISTIVITY OF A 0.254 MM THICK RECTANGULAR PARALLELEPIPED COPPER FOIL WAS MEASURED FROM 298 TO 77 K BY A SIMPLE FOUR-POINT PROBE TECHNIQUE WHERE PROBE WIRES ARE LEAD/TIN SOLDERED TO THE FOIL. RESISTIVITY DATA INDICATES THAT THE RESISTIVITY CORRECTION FACTOR IS APPROXIMATELY 2.8 FOR PROBES THAT ARE APPROXIMATELY 3 MM IN DIAMETER AND SPACED APPROXIMATELY 9 MM CENTER TO CENTER.
Details
- Original title: A METHOD OF MEASURING THE RESISTIVITY OF COPPER FROM 298 TO 77 K.
- Record ID : 1991-1059
- Languages: English
- Source: Rev. sci. Instrum. - vol. 61 - n. 12
- Publication date: 1990
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (3)
See the source
Indexing
- Themes: Thermodynamic measurements
- Keywords: Cryotemperature; Copper; Measurement; Electrical resistance
-
ELECTRICAL RESISTANCE OF SCREW-FASTENED THERMAL...
- Author(s) : OKAMOTO T.
- Date : 1990
- Languages : English
- Source: Rev. sci. Instrum. - vol. 61 - n. 4
View record
-
COMPUTER CONTROLLED LOW TEMPERATURE RESISTANCE ...
- Author(s) : BACIOCCO E., BORAGNO C., VALBUSA U.
- Date : 1989
- Languages : English
- Source: Cryogenics - vol. 29 - n. 3
View record
-
BEHAVIOUR OF THICK FILM RESISTORS AS LOW TEMPER...
- Author(s) : BOSCH W. A.
- Date : 1986
- Languages : English
- Source: Cryogenics - vol. 26 - n. 1
View record
-
CARBON COMPOSITION RESISTORS FOR CRYOGENIC THER...
- Author(s) : COSMO V. de
- Date : 1987
- Languages : English
- Source: Rev. sci. Instrum. - vol. 58 - n. 3
View record
-
A CARBON RESISTANCE THERMOMETER WITH FAST RESPO...
- Author(s) : ESKA G., NEUMAIER K.
- Date : 1983
- Languages : English
- Source: Cryogenics - vol. 23 - n. 2
View record