A new transient thermal fouling probe for cross flow tubular heat exchangers.

Author(s) : PEREZ L., LADEVIE B., TOCHON P., et al.

Type of article: Article

Summary

The present probe is developed in order to accurately estimate in situ not only the convective exchange coefficient but also the fouling thickness of heat exchangers from a reliable transient state estimation method. The originality of the estimation method consists in considering a global response time of the system in fouling conditions to be compared to clean conditions. The sensitivity function is then built from the experimental signal without precise knowledge about the model or the absolute thermophysical properties. The reliability of the method is demonstrated in theoretical cases and with calibrated experiments. [Reprinted with permission from Elsevier. Copyright, 2008].

Details

  • Original title: A new transient thermal fouling probe for cross flow tubular heat exchangers.
  • Record ID : 2009-1087
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 52 - n. 1-2
  • Publication date: 2009/01

Links


See other articles in this issue (8)
See the source