Summary
The balanced ambient room type calorimeter is generally used as the cooling capacity measurement standard equipment in the air conditioner industry. However, the calibration procedure is not investigated. In this study, based on the empty-load situation of calorimeter, the calibration model is proposed in order to restrain the error of heat balance caused by long-term use. Besides, two new parameters, which are background value of indoor-side and outdoor-side, are presented in accordance with the calibration model. Experiments are designed to obtain these two parameters and three heat leakage coefficients of partition wall, as well as the calibration procedure and application method of the parameters are illustrated. The corrected calorimeter measures ten different window type air conditioners in one year. The results show that the absolute value of heat balance is less than 2% in the cooling capacity range of 2000W~4500W and 1% in the range of 4500W~7000W.
Available documents
Format PDF
Pages: 8
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A practical calibration procedure for the balanced ambient room type calorimeter in testing the cooling capacity of room air conditioner.
- Record ID : 30025910
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.0456
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Heat balance; Calorimeter; Calibration; Measurement; Air conditioner; Cooling capacity; Model; Leakage
-
Condizionatori elettrici a due unità in aria in...
- Author(s) : ANGLESIO P., CAON S., CARUSO S.
- Date : 2001/01
- Languages : Italian
- Source: Cond. Aria - n. 1
View record
-
Uncertainty evaluation of cooling capacity meas...
- Author(s) : LU H.
- Date : 2011/04
- Languages : Chinese
- Source: HV & AC - vol. 41 - n. 249
- Formats : PDF
View record
-
Dynamic testing to better reflect real use for ...
- Author(s) : PALKOWSKI C., SCHWARZENBERG S., SIMO A.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
The low-cost design of the high efficiency ener...
- Author(s) : LIANG J.
- Date : 2010/09
- Languages : Chinese
- Source: Refrigeration - vol. 29 - n. 3
View record
-
Cooling load dynamics of rooms with cooled ceil...
- Author(s) : NIU J., KODI J. van de, REE H. van de
- Date : 1997
- Languages : English
- Source: Build. Serv. Eng. Res. Technol. - vol. 18 - n. 4
View record