IIR document
Dynamic testing to better reflect real use for the seasonal performance of air conditioners.
Number: pap. n. 672
Author(s) : PALKOWSKI C., SCHWARZENBERG S., SIMO A.
Summary
In this contribution, a dynamic test method to determine the seasonal performance of inverter type air conditioners has been developed and verified. In comparison to current test standards, where test modes for fixing the compressor speed are required, a dynamic approach is applied with unfixed compressor speed and thus better reflects the performance of air conditioners under real operating conditions. The dynamic tests are conducted in two calorimeter chambers. The indoor chamber is kept at a constant temperature whereas the outdoor chamber is subjected to a temperature profile based on the climate BIN-distribution, representing the reference cooling demand. The proposed dynamic test considers the dynamic control of an air conditioner and delivers results which could indicate the units’ performance in the field.
Available documents
Format PDF
Pages: 9
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Dynamic testing to better reflect real use for the seasonal performance of air conditioners.
- Record ID : 30026237
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.0672
Links
See other articles from the proceedings (632)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Seasonal performance; Calorimeter; Measurement; Air conditioner; Inverter; Temperature; Cooling capacity; Testing
-
Seasonal cooling performance of air conditioner...
- Author(s) : PALKOWSKI C., SCHWARZENBERG S., SIMO A.
- Date : 2019/08
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 104
- Formats : PDF
View record
-
A practical calibration procedure for the balan...
- Author(s) : HANG C., ZHANG H., XU D., et al.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Testing inverter type air conditioners for fiel...
- Author(s) : MAVURI S.
- Date : 2014/04
- Languages : English
- Source: EcoLibrium - vol. 13 - n. 3
- Formats : PDF
View record
-
Design of heat pipe heat sink used for cooling ...
- Author(s) : XIA G., ZHUANG D., DING G.
- Date : 2019/08/24
- Languages : English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
View record
-
Uncertainty evaluation of cooling capacity meas...
- Author(s) : LU H.
- Date : 2011/04
- Languages : Chinese
- Source: HV & AC - vol. 41 - n. 249
- Formats : PDF
View record