An air-source heat pump with substitute refrigerants working under low-temperature conditions.
Author(s) : WANG R. X., XIE G. Z., WU Y. Z.
Summary
The thermodynamic properties of propane and a non-azeotropic mixture refrigerant of R32/R125, R22 alternatives, were analysed. With the alternative refrigerants, firstly the basic requirements for designing an air-source heat pump and its key components were investigated. Then a new idea of heat compensation for an air-source heat pump that works at the condition of low temperature was put forward. Based on what mentioned above, a practical method used for reasonably analysing designing parameters, and optimally matching and choosing every parts for an air-source heat pump that works at the condition of low temperature was described. In addition, the control principle by adjusting the system itself by thermodynamic parameters to have higher efficiency when the system works at high environmental temperatures is discussed.
Details
- Original title: An air-source heat pump with substitute refrigerants working under low-temperature conditions.
- Record ID : 2006-2050
- Languages: English
- Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
- Publication date: 2003/04/22
Links
See other articles from the proceedings (166)
See the conference proceedings
Indexing
-
Themes:
Heat pumps techniques;
Hydrocarbons;
Blends - Keywords: R410A; Design; Air-water; Propane; Heat pump
-
Development and performance characterisation of...
- Author(s) : CORBERÁN J. M., GONZÁLVEZ J., MARTÍNEZ I. O., et al.
- Date : 2008/09/07
- Languages : English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
View record
-
Comparison of TEWI for fluorocarbon alternative...
- Author(s) : SAND J. R., FISCHER S. K., BAXTER D. van
- Date : 1999
- Languages : English
- Source: ASHRAE Transactions. 1999 Winter Meeting, Chicago, Illinois + CD-ROM.
View record
-
Assessment of propane as a refrigerant in resid...
- Author(s) : KELLER F. J., LIANG H., FARZAD M.
- Date : 1997/10/06
- Languages : English
- Source: Refrigerants for the 21st century. ASHRAE-NIST refrigerants Conference.
View record
-
Charge and COP optimization of a reversible wat...
- Author(s) : MARTÍNEZ I. O., GONZÁLVEZ J., CORBERÁN J. M.
- Date : 2006/05/29
- Languages : English
- Source: 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
View record
-
Prestaciones de bombas de calor cargadas con me...
- Author(s) : KANG D. G., PARK K. J., JUNG D.
- Date : 2010/05
- Languages : Spanish
- Source: IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 425
- Formats : PDF
View record