Summary
Although variable refrigerant flow (VRF) systems have become attractive due to good energy performances in part load conditions, the shortcoming of no outdoor air intake has not been solved thoroughly. A VRF and VAV combined air conditioning system is proposed to solve this problem. VAV part of the combined system consists of an outdoor air processing (OAP) unit and VAV boxes. Generally the VRF unit operates to maintain indoor temperature and the OAP unit operates to process the outdoor air. A control strategy for the combined system aiming at reducing energy consumption is presented in this paper. When both VRF unit and OAP unit are operating, a load allocation optimization module is executed to find the best load allocation between them to minimize the energy consumption of the combined system. When the allocated load of the OAP unit is very small, the proposed control strategy stops the OAP unit, leaving only the VRF unit to operate to improve the overall energy efficiency of the combined system. When load requirements are met, the OAP unit is restarted and the load allocation optimization module is executed again. The proposed control strategy is evaluated based on the developed simulation platform. Results show that the proposed control strategy can effectively decrease the energy consumption of the combined system.
Available documents
Format PDF
Pages: 11 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: An energy saving control strategy for VRF and VAV combined air conditioning system in heating mode.
- Record ID : 30013269
- Languages: English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2014/07/14
Links
See other articles from the proceedings (203)
See the conference proceedings
-
Online optimal control of variable refrigerant ...
- Author(s) : ZHU Y., JIN X., DU Z., et al.
- Date : 2015/04/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 80
View record
-
Experimental investigation on a novel temperatu...
- Author(s) : JIANG Y., GE T. S., WANG R. Z., et al.
- Date : 2014/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 73 - n. 1
View record
-
Experimental investigation on a novel temperatu...
- Author(s) : JIANG Y., GE T. S., WANG R. Z., et al.
- Date : 2014/12
- Languages : English
- Source: Applied Thermal Engineering - vol. 73 - n. 1
View record
-
Hydraulic balance regulation of air conditionin...
- Author(s) : QIN J., AN A.
- Date : 2012/09
- Languages : Chinese
- Source: HV & AC - vol. 42 - n. 268
- Formats : PDF
View record
-
Optimal control of combined air conditioning sy...
- Author(s) : ZHU Y., JIN X., FANG X., et al.
- Date : 2014/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 42
- Formats : PDF
View record