Analysis of a ground-source heat pump system operation utilizing steel foundation piles as ground heat exchangers.
Author(s) : KATSURA T., NAGANO K., HORI S., et al.
Summary
A ground-source heat pump (GSHP) system has been installed into a new building in Soen Campus of Sapporo City University. The GSHP system uses steel foundation piles as the ground heat exchangers. The construction works were carried out based on the design by using a design tool for GSHP systems that the authors have developed. The system has operated and the authors has analysed the system since April 2006. The result showed that steel foundation piles used as ground heat exchangers injected heat of around 250 W/m to the ground at the maximum during the cooling period. Also, it is expected the GSHP system in this building can operate with high efficiency for long term due to the ground water flow. The GSHP system can operate with average COP of more than 4.5 and reduce CO2 emission of 40% compared to a gas boiler system.
Details
- Original title: Analysis of a ground-source heat pump system operation utilizing steel foundation piles as ground heat exchangers.
- Record ID : 2009-0861
- Languages: English
- Source: 9th IEA Heat Pump Conference 2008: advances and prospects in technology, applications and markets. Conference proceedings [CD-ROM + abstracts].
- Publication date: 2008/05/20
Links
See other articles from the proceedings (45)
See the conference proceedings
Indexing
-
Themes:
Heat pumps techniques;
Other heat-pump applications - Keywords: Ground-water; Foundation; Concrete; Building; Heat pump; Performance; Expérimentation; School; Heat exchanger
-
Study on ground source heat pump system using c...
- Author(s) : WAKAYAMA H., KATSURA T., NAGANO K., et al.
- Date : 2012/12
- Languages : Japanese
- Source: Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan - n. 189
View record
-
Development of a ground-source heat pump system...
- Author(s) : SEKINE K., OOKA R., NAMATAME Y.
- Date : 2006/10
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 115
View record
-
Development of a ground-source heat pump system...
- Author(s) : SEKINE K., OOKA R., YOKOI M., et al.
- Date : 2007/01/27
- Languages : English
- Source: ASHRAE Transactions. 2007 Winter Meeting. Volume 113, part 1 + CD-ROM.
View record
-
Development of a ground-source heat pump system...
- Author(s) : SEKINE K., OOKA R., YOKOI M., et al.
- Date : 2006/02
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 107
View record
-
Development of a ground source heat pump system...
- Author(s) : OOKA R., SEKINE K., YOKOI M., et al.
- Date : 2005/05/02
- Languages : English
- Source: 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
View record