Analysis of air velocity and temperature distribution in furnished rooms with underfloor air diffusers.
Author(s) : CARLI M. de, PERON F., ROMAGNONI P., et al.
Summary
These proceedings in two volumes contain 198 papers presented at this conference, held in Reading, United Kingdom, 9-12 July 2000. The air distribution in occupied spaces is a major issue of public concern. It is widely recognized that the quality of air and the nature of airflow can affect the health of occupants and the energy consumed in buildings and transport vehicles. Chapters are: Volume 1: Keynote papers: provide good air quality for people and improve their productivity; the quality of buildings is equal to the indoor climate quality; optimised indoor air quality and energy saving strategies for quality buildings in Mediterranean climates: compatible objectives with comfort and environment issues? sustainability, energy and cost. indoor environment; predictive methods; air distribution. Volume 2: ventilation strategies; system efficiency; applications.
Details
- Original title: Analysis of air velocity and temperature distribution in furnished rooms with underfloor air diffusers.
- Record ID : 2002-0351
- Languages: English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
- Publication date: 2000/07/09
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (67)
See the conference proceedings
Indexing
- Themes: Other air-conditioning equipment
- Keywords: Velocity (fluids, gases); Floor; Measurement; Temperature; Air; Air conditioning; Air distribution
-
Thermal and ventilation characteristics in a ro...
- Author(s) : HAN H., CHUNG K. S., JANG K. J.
- Date : 1999/08/09
- Languages : English
View record
-
Studies on a pressurized type underfloor air-co...
- Author(s) : TAKAHASHI A., KONG C. N., NAKATANI H., OHWASE S.
- Date : 1996
- Languages : Japanese
- Source: Trans. JAR - vol. 13 - n. 2
View record
-
Flow and separation characteristics of horizont...
- Author(s) : RUTMAN E., INARD C., BAILLY A., et al.
- Date : 2000/07/09
- Languages : English
- Source: Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
View record
-
Temperature field measurement around the room a...
- Author(s) : AN K. H., LEE I. S.
- Date : 2000/11
- Languages : English
- Source: JSME int. J., B - vol. 43 - n. 4
View record
-
Experimental study on the floor-supply displace...
- Author(s) : AKIMOTO T., NOBE T., TAKEBAYASHI Y.
- Date : 1995/06/24
- Languages : English
- Source: ASHRAE Transactions.
View record