Application of Tandem System to high-efficiency refrigerator-freezer.

Summary

The Tandem System, a new approach for using two evaporators in a refrigerator-freezer system, has been developed. The system configuration, with two evaporators connected in series and appropriate controls, takes advantage of the transient operation to save energy. This system was applied to a commercial 18 cubic feet unit and a high-efficiency sample unit in which the thick insulation and energy-saving valve were used. The daily energy consumption for both units were reduced by 18% as compared to the baseline unit. In addition, a new defrost method, without using an electrical resistance heater was introduced, and the test was performed experimentally. This "internal defrost method", using the thermosiphon phenomenon between two evaporators, showed the potential of superior characteristics over the conventional approach.

Details

  • Original title: Application of Tandem System to high-efficiency refrigerator-freezer.
  • Record ID : 1997-0790
  • Languages: English
  • Source: ASHRAE Transactions.
  • Publication date: 1995/06/24
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles from the proceedings (79)
See the conference proceedings