IIR document
Assessment of evaporative cooling process across the mechanically driven cooling tower based on two-point boundary value problem using novel integral technique.
Author(s) : AADHITHIYAN A. A., SREERAJ R., NAIK B. N., ANBARASU S.
Type of article: IJR article
Summary
In the present study, a novel integral technique based on a two-point boundary value problem for the evaporative cooling process occurring across the mechanically driven counter flow cooling tower is structured and solved numerically. The developed technique is validated with the experimental data reported in the literature by choosing thermal load and vaporization rate as thermal performance evaluation parameters and observed the maximum deviation to be 13.5%. Moreover, the effect of inlet parameters on thermal load and vaporization rate is evaluated, and it is observed that water inlet temperature and air-specific humidity has a substantial influence on the performance of the cooling tower. Unique dimensionless parameters such as characteristic thermal mass of the packed column with tower height, heat difference ratio and moisture difference ratio along the height of the packed column, and number of heat-transfer units are introduced for assessing the performance as well as transfer characteristics of the cooling tower considering air as the cooling medium and water as the working fluid. The influence of various parameters such as Lewis number, number of heat and mass transfer units, fluid flow ratio, dimensionless thermal mass of the packed column with tower height, and moisture difference ratio on cooling tower efficiency is analyzed and observed that fluid flow ratio and moisture difference ratio have a significant impact on the thermal performance of the cooling tower. Further, for the given operating range, optimal values of number of heat transfer units, fluid flow ratio, and characteristic height of the cooling tower are predicted and found to be 0.87,0.35, and 0.8 m, respectively.
Available documents
Format PDF
Pages: 254-262
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Assessment of evaporative cooling process across the mechanically driven cooling tower based on two-point boundary value problem using novel integral technique.
- Record ID : 30029133
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Publication date: 2021/11
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2021.08.002
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (95)
See the source
-
A numerical simulation on recirculation phenome...
- Author(s) : LEE J. H., MOSHFEGHIAN M., CHI K. Y., et al.
- Date : 2014/11
- Languages : English
- Source: Applied Thermal Engineering - vol. 72 - n. 1
View record
-
Prediction of evaporation losses in evaporative...
- Author(s) : QURESHI B. A., ZUBAIR S. M.
- Date : 2007/02
- Languages : English
- Source: Applied Thermal Engineering - vol. 27 - n. 2-3
View record
-
An analytical model for the heat and mass trans...
- Author(s) : REN C. Q., YANG H. X.
- Date : 2006/02
- Languages : English
- Source: International Journal of Heat and Mass Transfer - vol. 49 - n. 3-4
View record
-
Flow and heat transfer characteristics of indir...
- Author(s) : WU X. P., YANG L. J., DU X. Z., et al.
- Date : 2014/05
- Languages : English
- Source: International Journal of thermal Sciences - vol. 79
View record
-
Modeling and simulation of counterflow wet-cool...
- Author(s) : LLANO-RESTREPO M., MONSALVE-REYES R.
- Date : 2017/02
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 74
- Formats : PDF
View record