Summary
Experiments were performed on flow boiling heat transfer and two-phase pressure drop of a refrigerant R410A flowing downward in a vertical small copper rectangular tube with 1.04 mm inside hydraulic equivalent diameter for the development of a high-performance heat exchanger using small tubes or multi-port extruded tubes for air conditioning systems. Local heat transfer coefficients were measured in a range of mass velocities from 30 to 200 kg/m2.s, heat fluxes from 1 to 16 kW/m2 and qualities from 0.05 to 1 at the evaporation temperature of 10°C. Pressure drops were also measured at mass velocities from 30 to 200 kg/m2.s and qualities from 0.1 to 0.9 at the saturation temperature of 10°C under the adiabatic condition. The characteristics of frictional pressure drop, heat transfer coefficient and dry-out quality were clarified by comparing the measurements with the data for the circular tube of 1.00 mm inside diameter previously obtained.
Available documents
Format PDF
Pages: 2009-5
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Boiling heat transfer and pressure drop of a refrigerant flowing vertically downward in a small rectangular tube.
- Record ID : 2009-1959
- Languages: English
- Source: 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Publication date: 2009/06/23
Links
See other articles from the proceedings (66)
See the conference proceedings
Indexing
-
Themes:
Heat transfer;
Two-phase flow;
Blends - Keywords: Two-phase flow; R410A; Geometry; Copper; Vertical tube; Heat transfer; Expérimentation; Heat exchanger; Boiling; Pressure drop
-
Two-phase pressure drop of R410A in small conse...
- Author(s) : CHEN I. Y., HU R., LIN S. Y., et al.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record
-
An improved two-phase pressure drop correlation...
- Author(s) : DOMANSKI P. A., HERMES C. J. L.
- Date : 2006/05/21
- Languages : English
- Source: ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
View record
-
Boiling heat transfer and pressure drop of R410...
- Author(s) : PAMITRAN A. S., CHOI K. I., OH J. T., et al.
- Date : 2009/05/20
- Languages : English
- Source: ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Formats : PDF
View record
-
Flow boiling heat transfer characteristics in h...
- Author(s) : PAMITRAN A. S., OH J. T., HRNJAK P., et al.
- Date : 2009/06/23
- Languages : English
- Source: 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
View record
-
Two phase flow boiling heat transfer and pressu...
- Author(s) : SMITH J., CREMASCHI L.
- Date : 2014/07/14
- Languages : English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record