IIR document
CFD simulations and measurements of carbon dioxide transport in a passive house.
Number: pap. n. 63
Author(s) : SZCZEPANIK N., SCHNOTALE J.
Summary
The airtightness of passive houses may cause the accumulation of contaminants within their structure. To determine, whether, and to what extent, this phenomenon occurs, measurements were performed in an existing passive house. The only considered indoor source of CO2 during measurements was human respiration, meaning that the CO2 concentration is strictly connected to the number of occupants and their lifestyle (Levin H., 2003) which is why it was chosen as an air quality indicator. Three cases where taken under consideration. First, carbon dioxide sensors where installed within the house for the period of four weeks, what enabled measuring the CO2 concentration. Next, a multizone simulation was conducted using the CONTAMW application. Finally, a CFD simulation was performed using the ANSYS Fluent software. In the final simulation, only the master bedroom was taken under consideration, as it was occupied frequently and had one of the highest concentrations of carbon dioxide. In the simulation the detailed breathing process was analyzed.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: CFD simulations and measurements of carbon dioxide transport in a passive house.
- Record ID : 30015097
- Languages: English
- Subject: Environment
- Source: Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Publication date: 2015/08/16
- DOI: http://dx.doi.org/10.18462/iir.icr.2015.0063
Links
See other articles from the proceedings (657)
See the conference proceedings
Indexing
-
Themes:
Indoor air quality;
Green buildings - Keywords: Building; Measurement; Air quality; Simulation; Natural cold; Concentration; CO2
-
Selecting CO2 criteria for outdoor air monitoring.
- Author(s) : LAWRENCE T. M.
- Date : 2008/12
- Languages : English
- Source: ASHRAE Journal - vol. 50 - n. 12
View record
-
Indoor environmental quality issues in low ener...
- Author(s) : KABELE K., DVORÁKOVÁ P.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Measuring IAQ parameters.
- Author(s) : BEARG D. W.
- Date : 2008/08
- Languages : English
- Source: HPAC Engineering - vol. 80 - n. 8
View record
-
Control of indoor fine particle concentration i...
- Author(s) : VIALLE J. P., PETIT P., HERVE G., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Ventilazione naturale.
- Author(s) : LENZUNI P., DEL GAUDIO M.
- Date : 2005/05
- Languages : Italian
- Source: Cond. Aria - n. 5
View record