Commercial refrigerated display cases with coolant: performance and energy consumption according to Italian standard UNI EN 441.
Banchi espositori commerciali a fluido secondario : valutazioni prestazionali e consumi energetici secondo la norma UNI EN 441
Author(s) : SCHIESARO P.
Type of article: Article
Summary
Tests were carried out on i) a vertical wall display case with operation temperature of 0 to 8 deg C and coolant water-propylene glycol; ii) a quick-frozen food island display case with frontal pane in the temperature range -22 to -24 deg C and coolant water-Tifoxite.
Details
- Original title: Banchi espositori commerciali a fluido secondario : valutazioni prestazionali e consumi energetici secondo la norma UNI EN 441
- Record ID : 1999-1588
- Languages: Italian
- Subject: Regulation
- Source: Industria italiana del Freddo - vol. 51 - n. 6
- Publication date: 1997/06
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles in this issue (1)
See the source
Indexing
-
Themes:
Supermarkets, display cabinets;
Industrial, commercial and domestic refrigeration: regulations and standards;
Refrigerating equipment: regulations and standards - Keywords: Standardization; Energy consumption; Display cabinet; Propylene glycol; Performance; Testing; Italy; Secondary refrigerant; Water
-
2006 Standard for performance rating of commerc...
- Author(s) : ARI
- Date : 2006
- Languages : English
View record
-
Method of testing open refrigerators.
- Author(s) : ASHRAE
- Date : 1999
- Languages : English
View record
-
Method of testing open refrigerators for food s...
- Date : 1997/11
- Languages : English
- Source: ASHRAE Stand. - BSR-ASHRAE Stand. 72-1983R; 17 p.; 6 fig.; 2 ref.
View record
-
Refrigerated display cabinets. 9. Electrical en...
- Author(s) : Stand. Aust.
- Date : 2000
- Languages : English
View record
-
Standard for commercial refrigerated display ca...
- Author(s) : ARI
- Date : 2002
- Languages : English
View record