COMPLEX ENERGY UTILISATION IN THE COMPUTER CENTRE OF BAUAKADEMIE BERLIN.

[In German. / En allemand.]

Author(s) : FEHST F., MAINKA C.

Type of article: Article

Summary

SALIENT FEATURES OF THE PLANT ARE THE UTILIZATION OF CONDENSER HEAT WITHIN THE AIR CONDITIONING SYSTEM AND INTERCONNECTION WITH THE BUILDING'S INSTALLATION SYSTEM. NECESSARY COMPENSATIONAL FUNCTIONS OF VARYING LOAD CYCLES ARE TAKEN OVER BY A THERMAL ENERGY LAMINATION STORE. IN CASE OF EXCESS WASTE HEAT THERE IS DISSIPATION VIA AN AIR COOLER THAT IS SUPPLIED WITH ADIABATICALLY COOLED AIR. PARTICULARLY ECONOMICAL CONDITIONS FOR CIRCUITRY EXECUTION ARE OFFERED BY PLANTS WITH HEAVY HEAT AND HUMIDITY LOADS. CONSEQUENTLY, THE SOLUTION DEVELOPED FOR COMPUTER AIR CONDITIONING IS ALSO APPLICABLE TO OTHER PLANT CONCEPTS.

Details

  • Original title: [In German. / En allemand.]
  • Record ID : 1982-2065
  • Languages: German
  • Publication date: 1981
  • Source: Source: Luft Kältetech.
    vol. 17; n. 3; 123-125; 4 fig.