COUNTERFLOW COOL DOWN OF CRYOGENIC POWER TRANSMISSION LINES.
Author(s) : DANEY D. E., JONES M. C.
Type of article: Article
Summary
COOL DOWN OF CRYOGENIC POWER TRANSMISSION LINES WHICH USE A COUNTERFLOW COOLING ARRANGEMENT IS INVESTIGATED ANALYTICALLY, NUMERICALLY, AND EXPERIMENTALLY. THE ACCURACY AND UTILITY OF A PREVIOUSLY REPORTED NUMERICAL COOL DOWN ARE ALSO CONFIRMED BY COMPARISON WITH EXPERIMENT.
Details
- Original title: COUNTERFLOW COOL DOWN OF CRYOGENIC POWER TRANSMISSION LINES.
- Record ID : 1982-0719
- Languages: English
- Source: Cryogenics - vol. 21 - n. 8
- Publication date: 1981