Critical stress on strain increase under constant load for SUS 316 LN austenitic-stainless steel at cryogenic temperature.

[In Japanese. / En japonais.]

Author(s) : TSUKAMOTO M., TOYODA M., MATSUMOTO T., SATOH H., WADAYAMA Y.

Type of article: Article

Summary

This austenitic-stainless steel is expected to be the material of superconducting toroidal coil case in the Tokamak fusion reactor. With round bar specimens, monotonic-loading tests were carried out at room temperature, 77 and 4.2 K, and constant-loading tests at room temperature and 77 K.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 1995-2714
  • Languages: Japanese
  • Source: Cryogenics/ Cryog. Eng. - vol. 29 - n. 5
  • Publication date: 1994
  • Document available for consultation in the library of the IIR headquarters only.