Standardization of low-cycle fatigue testing method at liquid-helium temperature.

[In Japanese. / En japonais.]

Author(s) : SUZUKI K.

Type of article: Article

Summary

Since 1991, nine organizations were involved in this co-operative study. Results obtained so far indicated that the typical rules needed for 4 K-testing were strain control error within more or less 4% and a strain rate of 0.4%/s or less at which the minimum temperature rise was assured to be 1 K or less.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 1995-3371
  • Languages: Japanese
  • Source: Cryogenics/ Cryog. Eng. - vol. 29 - n. 12
  • Publication date: 1994
  • Document available for consultation in the library of the IIR headquarters only.