CRYOGENIC LIQUID LEVEL MONITOR USING A FREQUENCY-TO-VOLTAGE CONVERTER.

Author(s) : COLLOCOTT S. J.

Type of article: Article

Summary

A SIMPLE CRYOGENIC LIQUID LEVEL MONITOR BASED ON A FREQUENCY-TO-VOLTAGE CONVERTER IS DESCRIBED. THE MONITOR, SIMPLE TO CONSTRUCT, OBVIATES THE NEED FOR SPECIAL TECHNIQUES TO ELIMINATE THE EFFECTS OF STRAY CAPACITANCE. IT HAS EXCELLENT LINEARITY, HIGH SENSITIVITY, AND USES A SIMPLE TWO-TERMINAL CAPACITANCE PROBE.

Details

  • Original title: CRYOGENIC LIQUID LEVEL MONITOR USING A FREQUENCY-TO-VOLTAGE CONVERTER.
  • Record ID : 1984-2181
  • Languages: English
  • Source: Cryogenics - vol. 23 - n. 6 1983.06
  • Publication date: 1983