DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP50.

Author(s) : LEE R., DEVOTTA S., HOLLAND F. A.

Type of article: Article

Summary

THE THEORETICAL RANKINE POWER CYCLE EFFICIENCIES AND THE PRESSURE RATIOS HAVE BEEN PRESENTED FOR RANKINE POWER CYCLES OPERATING ON PP50 (A PERFLUOROHYDROCARBON). THESE VALUES ARE LISTED IN TABULAR FORM FOR TEMPERATURE DROPS OF 10-75 K AND FOR BOILER TEMPERATURES 318-413 K (45-140 DEG C) IN 5 K INCREMENTS. A COMPOSITE GRAPH ILLUSTRATES THE FEASIBLE OPERATING RANGE FOR PP50 POWER CYCLE SYSTEMS. THE DERIVED THERMODYNAMIC DATA CAN BE USED FOR THE RAPID PRELIMINARY DESIGN OF RANKINE POWER CYCLE SYSTEMS.

Details

  • Original title: DERIVED THERMODYNAMIC DESIGN DATA FOR RANKINE POWER CYCLE SYSTEMS OPERATING ON PP50.
  • Record ID : 1985-2302
  • Languages: English
  • Source: J. Heat Recov. Syst. - vol. 4 - n. 6
  • Publication date: 1984
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (2)
See the source