IIR document
Design parametric study of a lateral configured diabatic straight capillary tube with R-134a.
Number: pap. n. 379
Author(s) : DUBBA S. K., KUMAR R.
Summary
An experimental investigation was conducted to observe the effect of sub-cooling degree on the mass flow rate of R-134a through a diabatic laterally configured straight capillary tube. The variation of mass flow rate of refrigerant through the capillary with the sub-cooling degree is observed to be independent of capillary tube geometry and the inlet pressure. When the diameter of the capillary tube decreased from 1.52 mm to 1.27 mm, the mass flow rate through the capillary tube also decreased by 16 percent. Also The mass flow rate of refrigerant was observed to increase by 12 to 17 percentage in all the tested capillary tubes with an increase of sub-cooling from 6°C to 9°C.
Available documents
Format PDF
Pages: 6
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Design parametric study of a lateral configured diabatic straight capillary tube with R-134a.
- Record ID : 30026413
- Languages: English
- Source: Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Publication date: 2019/08/24
- DOI: http://dx.doi.org/10.18462/iir.icr.2019.0379
Links
See other articles from the proceedings (632)
See the conference proceedings
-
A generalized correlation for refrigerant mass ...
- Author(s) : CHOI J., KIM Y., KIM H. Y.
- Date : 2003/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 8
- Formats : PDF
View record
-
Assessment of pulse-width modulated flow throug...
- Author(s) : RONZONI A. F., HERMES C. J. L., MELO C.
- Date : 2013/01
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 1
- Formats : PDF
View record
-
Experimentation and modelling of refrigerant fl...
- Author(s) : PARK C., LEE S., KANG H., et al.
- Date : 2007/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 7
- Formats : PDF
View record
-
Experimental study of R600a mass flow rate in n...
- Author(s) : RASTI M., HASAN M. R., JEONG J. H.
- Date : 2022/06/13
- Languages : English
- Source: 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Formats : PDF
View record
-
R-152a as an alternative refrigerant to R-134a ...
- Author(s) : MAIORINO A., APREA C., DEL DUCA M. G., et al.
- Date : 2018/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 96
- Formats : PDF
View record