Drop-in testing of next-generation R134a alternates in a commercial bottle cooler/freezer.
Number: pap. 2153
Author(s) : SHAPIRO D.
Summary
Next-generation refrigerants with lower Global Warming Potentials than traditional HFC’s are being commercially introduced. Drop-in performance tests were conducted in a commercial bottle cooler/freezer. Tests were conducted with R134a as a baseline and several next-generation refrigerants and blends. The tests were conducted in accordance with ASHRAE Standard 72 at -5.6 and 3.3°C bottle cooler temperature setpoints. Two ambient conditions were tested, 23.9°C/55% relative humidity and 26.7°C/55% relative humidity. In addition to the ASHRAE test conditions, full pull-down and half pull-down tests were conducted in accordance with a soft-drink bottler’s specifications. Performance parameters such as discharge air temperatures, product simulator temperatures, suction pressure, discharge pressure, compressor mass flow rate, and compressor input power were measured and compared. With the exception of HFO-1234ze(E), all the substitute refrigerants had similar performance as R134a. HFO-1234ze(E) had lower density at compressor suction conditions and therefore resulted in longer compressor run times and longer pull-down times. A larger displacement compressor would likely bring HFO-1234ze(E) to roughly the same performance as the other refrigerants.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Drop-in testing of next-generation R134a alternates in a commercial bottle cooler/freezer.
- Record ID : 30006324
- Languages: English
- Source: 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2012/07/16
Links
See other articles from the proceedings (195)
See the conference proceedings
Indexing
-
Themes:
HFCs;
Supermarkets, display cabinets - Keywords: R1234yf; Commercial application; Beverage; R1234ze; Substitute; Performance; Testing; Refrigerant; Vending machine
-
HFO-1234yf performance in a beverage cooler.
- Author(s) : MINOR B., MONTOYA C., KASA F. S.
- Date : 2010/07/12
- Languages : English
- Source: 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Analysis of LGWP alternatives for small refrige...
- Author(s) : YANA-MOTTA S. F., BECERRA E. D. V., SPATZ M. W.
- Date : 2010/07/12
- Languages : English
- Source: 2010 Purdue Conferences. 13th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Low GWP R134a replacements for small refrigerat...
- Author(s) : SETHI A., BECERRA E. V., YANA MOTTA S.
- Date : 2016/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 66
- Formats : PDF
View record
-
Analysis of low-GWP alternatives for small refr...
- Author(s) : YANA MOTTA S., SPATZ M., BECERRA E. V.
- Date : 2011/08/21
- Languages : English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
View record
-
Sistema de monitorização em tempo real para máq...
- Author(s) : CARVALHO R., ARAUJO A., OLIVEIRA A., et al.
- Date : 2016/05/03
- Languages : Portuguese
- Source: CYTEF 2016. VIII Congreso Ibérico y VI Congreso Iberoamericano de las Ciencias y Técnicas del Frío, Coimbra-Portugal, 3-6 mayo, 2016.
- Formats : PDF
View record