IIR document
Dynamic characteristics of a R410A split air-conditioning system.
Author(s) : KIM M. H., BULLARD C. W.
Type of article: Article, IJR article
Summary
The paper presents experimental results on the shut-down and start-up characteristics of a residential split system R410A air-conditioner with a capillary tube. During shut-down, the transient characteristics are evaluated by measuring the high and low side pressures and temperatures of the system. The dynamic behaviour of the system after start-up is also investigated at the standard cooling capacity rating condition of which the dry and wet bulb temperatures for the indoor and outdoor are 27/19.5 and 35/24 °C, respectively. All experiments are performed in a psychrometric calorimeter. The cooling capacity, power consumption, dehumidification capacity and cycle characteristics after start-up are analyzed. The test results show that the cooling capacity and the COP after start-up can be expressed as the combination of two exponential functions of time, approaching the cooling capacity of steady-state.
Available documents
Format PDF
Pages: 652-659
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Dynamic characteristics of a R410A split air-conditioning system.
- Record ID : 2001-2874
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 7
- Publication date: 2001/11
Links
See other articles in this issue (10)
See the source
Indexing
-
Themes:
Other air-conditioning equipment;
Blends - Keywords: Split system; R410A; Operation; Capillary; Air conditioner; On-off; Performance; Refrigerant; Air conditioning
-
Alkylbenzenes for split air conditioners with R...
- Author(s) : SUMIDA Y., NAKAYAMA M., SUZUKI S., KAWAGUCHI S.
- Date : 1998/07/14
- Languages : English
- Source: Proceedings of the 1998 International Compressor Engineering Conference at Purdue (ICECP 1998).
View record
-
The performance evaluation of a room air condit...
- Author(s) : TAIRA S., YAZIMA R., KOYAMA S.
- Date : 2001
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 3
View record
-
Propane as refrigerant in a reversible split ty...
- Author(s) : ALOISI A.
- Date : 2000/12/07
- Languages : English
- Source: The International Symposium on HCFC Alternative Refrigerants and Environmental Technology 2000: Latest technology for Energy Conservation, Refrigerants and Recycling on Air-Conditioning and Refrigeration Equipment for the 21st century. Proceedings.
View record
-
Evaluation and modelling of split-system air co...
- Author(s) : RICE C. K.
- Date : 2005/12
- Languages : English
View record
-
Capillary tube selection for HCFC-22 alternatives.
- Author(s) : JUNG D., PARK C., PARK B.
- Date : 1999/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 22 - n. 8
- Formats : PDF
View record