Enhancement of boiling heat transfer in a 5 x 3 tube bundle.

Author(s) : GUPTA A.

Type of article: Article

Summary

The results of an experimental investigation on nucleate boiling heat transfer in an electrically heated 5 x 3 in-line horizontal tube bundle under pool and low cross-flow conditions of saturated water near atmospheric pressure are presented here. It is observed that the heat transfer coefficient is minimum on bottom row tubes and increases in the upward direction with maximum values on top row tubes. Also, heat transfer coefficient on central column tubes was found to be slightly higher than those on the corresponding side tubes. Further, a Chen-type relation has been used to determine the local boiling heat transfer coefficient on a tube in a heated tube bundle.

Details

  • Original title: Enhancement of boiling heat transfer in a 5 x 3 tube bundle.
  • Record ID : 2006-0643
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 48 - n. 18
  • Publication date: 2005/08