Exergy and energy analysis of waste heat recovery options for cooling capacity production.
Number: pap. 2344
Author(s) : MAATOUK C., SLIM R.
Summary
Electricity production in Lebanon stands at around 1.5 GW while the demand exceeds 2.5 GW at peak times and peak cooling demands, resulting in rationing cuts from between 3 to 20 hours a day which is the worst performance in the Middle East. Due to the country energy shortfall, a large number of small-scale backup generators is installed to address the electric and cooling needs. The proliferation of use of these backup generators presents an interesting potential for waste heat recovery in order to achieve additional power generation and cooling capacity production. This paper investigates two possible configurations for waste heat recovery: A first configuration studies the potential of combining an Organic Rankine Cycle (ORC) with a conventional vapor compression refrigeration cycle (VCRC) to meet the required cooling load. A second option evaluates the possibility of using a liquid desiccant cooling system (LDCS) to handle the latent part of the cooling load, in tandem with a conventional vapor compression refrigeration cycle handling the sensible part. The investigations are based on exergy and energy analysis carried out for both configurations to assess and compare their performance.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Exergy and energy analysis of waste heat recovery options for cooling capacity production.
- Record ID : 30013224
- Languages: English
- Source: 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Publication date: 2014/07/14
Links
See other articles from the proceedings (203)
See the conference proceedings
Indexing
-
Themes:
Other energy-saving and energy-recovery systems;
Ejector systems, air cycle, Stirling cycle, other cycles);
Other refrigerating systems (desiccant cooling, thermoelectrics, thermoacoustics…);
Energy efficiency, energy savings - Keywords: Rankine; Exergy; Energy; Comparison; Cooling; Heat recovery; Performance; Modelling; Desiccant; Waste heat
-
Dynamic analysis of energy recovery utilizing t...
- Author(s) : ANDRESEN T., LINGAAS S., HAGEN B. A. L., NEKSÅ P.
- Date : 2020/07/31
- Languages : English
- Source: IIR Rankine Conference 2020.
- Formats : PDF
View record
-
Utilization of waste heat from GT-MHR for power...
- Author(s) : YARI M., MAHMOUDI S. M. S.
- Date : 2010/04
- Languages : English
- Source: Applied Thermal Engineering - vol. 30 - n. 4
View record
-
Low GWP working fluids for reversible systems o...
- Author(s) : PERIS PÉREZ B., NAVARRO-ESBRÍ J., MOLÉS F., et al.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record
-
Thermo-economic optimization of an ORC driven h...
- Author(s) : MOUNIER V., MENDOZA L. C., SCHIFFMANN J.
- Date : 2017/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 81
- Formats : PDF
View record
-
Numerical investigation on a heat-driven free-p...
- Author(s) : LUO K., ZHANG L., HU J., LUO E., WU Z., SUN Y., ZHOU Y.
- Date : 2021/10
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 130
- Formats : PDF
View record