Experimental evaluation of a downsized residential air distribution system: comfort and ventilation effectiveness.
Author(s) : JALALZADEH-AZAR A. A.
Summary
New challenges surrounding air-distribution effectiveness have emerged from downsizing of the HVAC systems in energy-efficient residential buildings. As a result of downsizing, the system design flow rates are significantly reduced- potentially leading to poor air mixing and undesirable spatial temperature patterns and, consequently, adversely affecting the comfort level and ventilation effectiveness. Unless these challenges are successfully met, the system downsizing trend, as well as the efforts to implement related energy-saving measures, will be undermined. This paper examines the performance of a prevalent air-distribution configuration incorporating a high sidewall supply air diffuser and a near-floor, wall-mounted return air grille in a test room during a period of recovery from setback. To address the aforementioned issues of interest, tracer-gas tests were conducted along with spatial temperature measurements in the room. In the experiments, two levels of supply airflow rate were considered, low and high, of which the latter is comparable to the design range commonly applied in standard- practice residential buildings. The results indicated that, at the lower flow rate and velocity, both ventilation effectiveness and comfort were compromised because of stratification. The constraints with the trace-gas instrumentation led to inconclusive results with respect to air mixing and ventilation effectiveness. To overcome this limitation, a frame of reference was introduced for a more accurate assessment of the experimental system performance. The analytical solutions for an ideal case in which the indoor air was perfectly mixed at any given instant provided the reference points for comparison.
Details
- Original title: Experimental evaluation of a downsized residential air distribution system: comfort and ventilation effectiveness.
- Record ID : 2008-1761
- Languages: English
- Source: ASHRAE Transactions. 2007 Annual Meeting, Long Beach, CA. Volume 113, part 2 + CD-ROM.
- Publication date: 2007/06/23
Links
See other articles from the proceedings (22)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Geometry; Air diffuser; Performance; Residential building; Expérimentation; Air conditioning; Air distribution
-
Design and experimental research of swirling co...
- Author(s) : ZHOU D., SHI C., YUAN W.
- Date : 2011/08/21
- Languages : English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
View record
-
Evaluation of temperature distributions and air...
- Author(s) : SOHN J. Y., AHN B. W., PARK J. S., et al.
- Date : 1999/08/09
- Languages : English
View record
-
Mathematical modeling of air supply conditions ...
- Author(s) : TIRPÁK T.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
The effect of various air-terminal geometries o...
- Author(s) : STEIMLE F., SCHADLICH S.
- Date : 1994/11/16
- Languages : German
- Source: DKV-Tagungsbericht 1994 Bonn.
View record
-
Review of air flow regimes and thermal comfort ...
- Author(s) : ASHMAWY M.E., KHALIL E. E.
- Date : 2017/07/20
- Languages : English
- Source: 8th international conference on compressors and refrigeration, 2017.
- Formats : PDF
View record