EXPERIMENTAL RESULTS FOR A CRYOCOOLER REGENERATOR.

Author(s) : GAMBARDELLA U., ORAZI A.

Type of article: Article

Summary

IN THIS WORK SOME EXPERIMENTAL RESULTS OBTAINED ON A SINGLE STAGE GIFFORD-MCMAHON CRYOCOOLER FOR INFRARED THERMAL VISION APPLICATIONS ARE PRESENTED. THE DIFFERENCE IN THERMODYNAMIC BEHAVIOUR OF THREE ORDINARY AND EASY TO FIND MESHED NETS USED IN THE CRYOCOOLERS AS A MATRIX FOR THE THERMAL REGENERATOR HAS BEEN CHECKED. THE METHOD USED TO DETECT THE REGENERATOR PERFORMANCE IS INDIRECT BUT VERY SIMPLE TO PUT INTO PRACTICE AND USEFUL FOR AN OVERALL EVALUATION. A CLEAR INDICATION FOR THE CHOICE OF THE REGENERATOR MATERIAL COMES FROM THE EXPERIMENTAL DATA.

Details

  • Original title: EXPERIMENTAL RESULTS FOR A CRYOCOOLER REGENERATOR.
  • Record ID : 1985-1803
  • Languages: English
  • Source: Cryogenics - vol. 25 - n. 1
  • Publication date: 1985