Experimental study of thermal environment and comfort in an office room with a variable air volume system under low supply air temperature conditions.
Author(s) : MARIPUU M. L.
Summary
The air distribution components in a variable air volume flow system influences the overall function of the system. A low supply air temperature and a wide working range in terms of airflow rate, facilitate high energy efficiency. However, in order to achieve these properties, high demands must be set on the function of the supply-air diffusers. This paper analyzes the thermal environment and comfort in an office room where the supply air diffusers have been chosen in accordance with such high demands. The study involves determining thermal comfort properties under different flow conditions and with a low supply air temperature, about 15°C, in a full scale test room. It also includes measured velocity profiles and calculated draught ratings. The results indicate that the risk of draught was quite low despite high airflow rates and a low supply air temperature with the studied type of a supply-air device.
Details
- Original title: Experimental study of thermal environment and comfort in an office room with a variable air volume system under low supply air temperature conditions.
- Record ID : 2008-2679
- Languages: English
- Source: Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
- Publication date: 2007/06/10
Links
See other articles from the proceedings (76)
See the conference proceedings
Indexing
-
Themes:
Other air-conditioning equipment;
Comfort air conditioning - Keywords: Variable volume; Office; Geometry; Building; Ventilation; Air diffuser; Air; Air conditioning
-
DUAL-DUCT VARIABLE AIR VOLUME: DESIGN/BUILD VIE...
- Author(s) : LINFORD R. G.
- Date : 1987
- Languages : English
View record
-
Climatisation réversible de 2100 m2 de bureaux ...
- Date : 2006/04
- Languages : French
- Source: Chaud Froid Plomb. - n. 689
View record
-
A novel variable air volume system.
- Author(s) : SIGANTO J. J. W., NOBLE P. J.
- Date : 2005/02
- Languages : English
- Source: EcoLibrium - vol. 4 - n. 1
View record
-
Rating modern office air conditioning systems o...
- Author(s) : LEDERER S., ROTH H. W., HANDEL C.
- Date : 1993/07
- Languages : German
- Source: Klima Kälte Heiz. - vol. 21 - n. 7-8
View record
-
EXPERIENCE WITH VARIABLE VOLUME AIR CONDITIONIN...
- Author(s) : RAKOCZY T.
- Date : 1982/04
- Languages : German
- Source: Gesund. Ing. - vol. 103 - n. 2
View record