Experimental study on two kinds of heat exchangers in four-way-valve heat pump system of electric vehicle.

[In Chinese. / En chinois.]

Author(s) : YAN R., WANG Y., GAO T., et al.

Type of article: Article

Summary

Low efficiency of PTC in electrical vehicles would cut down its travelled distance, so it' s necessary to design high efficiency heat pump system. Two kinds of heat exchangers were used as outside heat exchangers (HX) in four-way-valve heat pump system, and experimental study was finished under both heating and cooling modes. The results showed, under low face velocity in heating model, small diameter tube HX had higher capacity by 10.5%, and the same COP compared with parallel flow HX. Under
low face velocity in cooling model, small diameter tube HX had higher capacity by 3.8% , and higher COP by 22.8% compared with parallel flow HX. With the increasing of wind velocity, capacity and COP with small diameter tube HX increased little; however, the one with parallel flow HX had a higher increasing. It is concluded that heat pump system used small diameter tube HX had a potential prospect under low wind velocity.

Available documents

Format PDF

Pages: 65-69

Available

  • Public price

    20 €

  • Member price*

    15 €

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details


Links


See other articles in this issue (6)
See the source