Field experiences in three supermarkets in Sweden.
Author(s) : ARIAS J., LUNDQVIST P.
Summary
The replacement of CFC and HCFC refrigerants and the effective use of energy have influenced the refrigeration systems in supermarkets. New solutions with energy efficient equipment and completely indirect refrigeration systems have been developed to decrease the energy use and to minimise the refrigerant charge. A computer program that calculates the energy use in a supermarket with different innovative solutions can be a good tool when designing a refrigeration system. The computer model must be able to deal with technical solutions, investment economics and environmental impact for supermarket refrigeration systems. To validate the computer program it is necessary to compare the numerical results with field experience. Measurements of different parameters such as temperatures, relative humidity and compressor power started in three supermarkets last year and the results from these measurements are presented in the paper.
Details
- Original title: Field experiences in three supermarkets in Sweden.
- Record ID : 2005-0889
- Languages: English
- Source: Advanced supermarket refrigeration/heat recovery systems. Workshop proceedings [CD-ROM].
- Publication date: 2000/10/02
Links
See other articles from the proceedings (11)
See the conference proceedings
-
Introduction of an 'energy goodness' number for...
- Author(s) : RASMUSSEN B. D., MUNTER P., HOLM H. V., et al.
- Date : 2000/10/02
- Languages : English
- Source: Advanced supermarket refrigeration/heat recovery systems. Workshop proceedings [CD-ROM].
View record
-
New heat recovery and defrost methods for super...
- Author(s) : MINEA V., DUBÉ S., KANTCHEV J.
- Date : 2000/10/02
- Languages : English
- Source: Advanced supermarket refrigeration/heat recovery systems. Workshop proceedings [CD-ROM].
View record
-
Energy analysis of a supermarket refrigeration ...
- Author(s) : JENSEN J. M., RASMUSSEN B. D., JAKOBSEN A., et al.
- Date : 1999/08
- Languages : English
- Source: ScanRef - n. 4
View record
-
EVALUATION DES CONTROLES MECANIQUES DANS UN ENT...
- Author(s) : DUPONT L., BERG L. B. van den, ROOKE E. A.
- Date : 1982/04/16
- Languages : French
- Source: Agric. Can., Dir. gén. Rech., Inst. Rech. tech. stat., Programme RDEAA - dossier n. 11SD.01843-1-EC07
View record
-
Planung und Betriebsverfolgung von Ammonia/Sole...
- Author(s) : BLINDAUER C., RIESENBECK G. van
- Date : 1998/11/18
- Languages : German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
View record