Summary
Falling film is the typical configuration of the evaporator of LiBr-H2O absorption chillers. However, this type of configuration requires usually an additional refrigerant pump to take the maximum advantage of the heat transfer area. For small capacity absorption chillers it is interesting to remove the refrigerant pump, to reduce the final price. An interesting alternative is flooded evaporators. Their design presents the main difficult of dealing with lower heat transfer coefficients with respect falling film ones. Therefore, could be necessary to increase the heat transfer area in such heat exchangers. In this work, a model for the design and prediction of flooded evaporators is presented. The model is validated with experimental data of other authors of two tube-fin flooded evaporators. The agreement is under 20% in the prediction of the heat exchanged. Finally, an example of design for a small capacity LiBr-H2O machine is presented.
Available documents
Format PDF
Pages: 2008-2
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Flooded evaporators for LiBr-H2O absorption chillers: modelling and validation.
- Record ID : 2009-0069
- Languages: English
- Source: 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Publication date: 2008/09/07
Links
See other articles from the proceedings (132)
See the conference proceedings
-
Direct-heat exchange water evaporator for vapou...
- Author(s) : EAMES I. W., WU S., SABIR H.
- Date : 1998/06/02
- Languages : English
- Source: Natural Refrigerants, Energy Efficiency, Cost and Safety. Natural Working Fluids '98. IIR-Gustav Lorentzen Conference.
- Formats : PDF
View record
-
Low pressure showered evaporator in absorption ...
- Author(s) : CURKA D., MOLOTTA M.
- Date : 2009/09/02
- Languages : English
- Source: Compressors 2009: 7th International Conference on Compressors and Coolants
- Formats : PDF
View record
-
Non-absorbable gas control in the absorber/evap...
- Author(s) : SUZUKI H., ISHIGAMI T., YAMADA M., et al.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record
-
An experimental study on plate type solution he...
- Author(s) : SONG J., LEE S. K., KANG Y. T.
- Date : 2017/08/07
- Languages : English
- Source: International sorption heat pump conference, ISHPC 2017, Tokyo august 7-10.
View record
-
Performance evaluation of plate heat exchanger ...
- Author(s) : SONG J. Y., CHANG Y. S., KANG Y. T.
- Date : 2018/06/18
- Languages : English
- Source: 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
View record