GENERALIZED PREDICTION OF HEAT TRANSFER DURING SUBCOOLED BOILING IN ANNULI.

Author(s) : SHAH M. M.

Type of article: Article

Summary

THE DATA INCLUDE THE FLUIDS WATER, R113 AND METHANOL ; MASS FLUXES FROM 278 TO 7,774 KG/M2S ; HEAT FLUXES FROM 0.03 TO 4.4 MW/M2 ; SUBCOOLING FROM 275 TO 382 K (2 TO 109 DEG C) ; AND REDUCED PRESSURES FROM 0.009 TO 0.89. THE INNER TUBE DIAMETER VARIED FROM 4.5 TO 42.2 MM AND THE ANNULAR GAP FROM 1 TO 6.6 MM. THE 450 REPRESENTATIVE DATA POINTS ARE CORRELATED WITH A MEAN DEVIATION OF 8.9%.

Details

  • Original title: GENERALIZED PREDICTION OF HEAT TRANSFER DURING SUBCOOLED BOILING IN ANNULI.
  • Record ID : 1983-2117
  • Languages: English
  • Source: Heat Transf. Eng. - vol. 4 - n. 1
  • Publication date: 1983/01
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (1)
See the source