HEAT TRANSFER LIMITATION IN A VERTICAL ANNULAR CLOSED TWO-PHASE THERMOSYPHON WITH SMALL FILL RATES.
Author(s) : ROSLER S.
Type of article: Article
Summary
A THERMOSYPHON WITH R113 AS THE WORKING FLUID EMPLOYING FILL RATIOS BETWEEN 0.02 AND 0.4, IE 2 AND 40% OF THE EVAPORATOR VOLUME, WAS EXPERIMENTALLY AND THEORETICALLY INVESTIGATED. A CRITICAL HEAT FLUX (FOR WHICH DRY-OUT OCCURS) WAS MEASURED WHICH INCREASES FROM ABOUT 10 KILOW/M2 AT 5% FILL RATIO TO ABOUT 50 KILOW/M2 AT 40% FILL RATIO. THE THEORETICAL PREDICTIONS ARE IN CLOSE AGREEMENT WITH THE EXPERIMENTAL RESULTS.
Details
- Original title: HEAT TRANSFER LIMITATION IN A VERTICAL ANNULAR CLOSED TWO-PHASE THERMOSYPHON WITH SMALL FILL RATES.
- Record ID : 1988-0082
- Languages: English
- Source: Heat Recov. Syst. CHP - vol. 7 - n. 4
- Publication date: 1987
Links
See other articles in this issue (4)
See the source
Indexing
- Themes: Heat transfer
- Keywords: Heat pipe; Calculation; Measurement; Heat transfer; Thermosyphon; R113; Performance
-
HEAT TRANSFER CHARACTERISTICS IN TWO-PHASE CLOS...
- Author(s) : FAGHRI A., CHEN M. M., MORGAN M.
- Date : 1989
- Languages : English
- Source: J. Heat Transf. - vol. 111 - n. 3
View record
-
FLOW AND HEAT TRANSFER CHARACTERISTICS IN A CLO...
- Author(s) : IMURA H., SAITO Y., FUJIMOTO H.
- Date : 1989
- Languages : Japanese
- Source: Trans. JAR - vol. 6 - n. 2
View record
-
OPERATING CHARACTERISTICS OF AN AIR-TO-WATER HE...
- Author(s) : KAMIYA Y., CHENG K. C., TAKUMA M.
- Date : 1989
- Languages : Japanese
- Source: Transaction of the Society of Heating, Air-conditioning and Sanitary Engineers of Japan - n. 41
View record
-
MAXIMUM HEAT TRANSFER IN THERMOSIPHONS WITH SEP...
- Author(s) : BEZRODNYY M. K., VOLKOV S. S., ALEKSEYENKO D. V.
- Date : 1983
- Languages : English
- Source: Heat Transf., Sov. Res. - vol. 15 - n. 2
View record
-
EVAPORATOR PERFORMANCE OF TWO-PHASE THERMOSIPHO...
- Author(s) : MATHUR G. D., MCDONALD T. W.
- Date : 1988
- Languages : English
View record