Summary
The impedance magnitude is important for the design and operation of a Stirling pulse tube cryocooler (SPTC). However, the influence of the impedance magnitude on the SPTC working at liquid-helium temperatures is still not clear due to the complexity of refrigeration mechanisms at this temperature range. In this study, the influence of the impedance magnitude on the viscous and thermal losses has been investigated, which contributes to the overall refrigeration efficiency. Different from the previous study at liquid nitrogen temperatures, it has been found and verified experimentally that a higher impedance magnitude may result in a larger mass-flow rate accompanied with larger losses in the warmer region, hence the refrigeration efficiency is lowered. Numerical simulation is carried out in SPTCs of different geometry dimensions and working parameters, and the experimental study is carried out in a three-stage SPTC. A minimum no-load refrigeration temperature is achieved with an appropriate impedance magnitude that is determined by the combination of frequency and precooling temperature. A lowest temperature of 4.76 K is achieved at 28 Hz and a precooling temperature of 22.6 K, which is the lowest temperature ever achieved with He-4 for SPTCs. Impedance magnitude optimization is clearly an important consideration for the design of a 4 K SPTC.
Details
- Original title: Impedance magnitude optimization of the regenerator in Stirling pulse tube cryocoolers working at liquid-helium temperatures.
- Record ID : 30009576
- Languages: English
- Source: Cryogenics - vol. 58
- Publication date: 2013/12
- DOI: http://dx.doi.org/10.1016/j.cryogenics.2013.09.007
Links
See other articles in this issue (8)
See the source
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Pulse tube; Impedance; Regenerator; Stirling; Optimization; Cryocooler
-
Theoretical analysis of a pulse tube regenerator.
- Author(s) : ROACH P. R., KASHANI A., LEE J. M.
- Date : 1996/07/17
- Languages : English
- Source: Advances in cryogenic engineering.
View record
-
A new tapered regenerator used for a pulse tube...
- Author(s) : LIU Y. W., HE Y. L.
- Date : 2008/11
- Languages : English
- Source: Cryogenics - vol. 48 - n. 11-12
View record
-
Phase shifters in a high frequency pulse-tube c...
- Author(s) : MA J., HOU Y. K., LONG X. H., et al.
- Date : 2003/04/22
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
View record
-
Coupling study of a novel thermocompressor driv...
- Author(s) : JI W., XUE X., WANG J., et al.
- Date : 2013/03
- Languages : English
- Source: Applied Thermal Engineering - vol. 51 - n. 1-2
View record
-
REGENERATOR ANALYSIS IN AN ORIFICE PULSE TUBE R...
- Author(s) : RAWLINS W., TIMMERHAUS K. D., RADEBAUGH R.
- Date : 1991/08/10
- Languages : English
- Source: New challenges in refrigeration. Proceedings of the XVIIIth International Congress of Refrigeration, August 10-17, 1991, Montreal, Quebec, Canada.
- Formats : PDF
View record