IIR document
Influence of adsorption cycle limitations on the system performance.
Author(s) : CERKVENIK B., POREDOS A., ZIEGLER F.
Type of article: Article, IJR article
Summary
To show the basic differences between absorption and adsorption cycle optimization, and also to show the impact of physical or technical limitations on the adsorption chiller performance, a detailed analysis has been performed. It is confirmed that it is mainly the lack of a solution heat exchanger which lowers the adsorption system COP and not physical properties of the working pair, so there is still a lot of room for improvement in the solid-sorption heat pumps.
Available documents
Format PDF
Pages: 475-485
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Influence of adsorption cycle limitations on the system performance.
- Record ID : 2001-2728
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 6
- Publication date: 2001/09
Links
See other articles in this issue (11)
See the source
Indexing
- Themes: Absorption and adsorption systems
- Keywords: Refrigerating system; Absorption system; Adsorption system; Performance; Parameter
-
Air conditioning without compression refrigerat...
- Author(s) : REINMUTH F.
- Date : 1997/12
- Languages : German
- Source: Tech. Bau - n. 12
View record
-
A novel type of coupling cycle for adsorption h...
- Author(s) : WANG S. W., ZHU D. S.
- Date : 2002/06
- Languages : English
- Source: Applied Thermal Engineering - vol. 22 - n. 9
View record
-
A novel parametric analysis of a conventional s...
- Author(s) : ALAM K. C. A., SAHA B. B., AKISAWA A., et al.
- Date : 2000
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 17 - n. 3
View record
-
Sorption refrigeration/heat pump cycles.
- Author(s) : SAHA B. B., ALAM K. C. A., HAMAMOTO Y., et al.
- Date : 2001
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 18 - n. 1
View record
-
Modelling the performance of two-bed, silica ge...
- Author(s) : CHUA H. T., NG K. C., MALEK A., KASHIWAGI T., AKISAWA A., SAHA B.
- Date : 1999/05
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 22 - n. 3
- Formats : PDF
View record