Influence of so-called high pressure refrigerants on the compressor design.

Einfluss sogenannter Hochdruckkältemittel auf die Verdichterkonstruktion.

Author(s) : KAISER H.

Type of article: Article

Summary

With the introduction of new and pollution free refrigerants (e.g. R410A, CO2), the constructional request increase, since on the high pressure side pressures over 25 bars is necessary. The necessary modifications at the refrigeration compressors of the reciprocating piston design are described for adjustment to 40 bars as well as the development of the newest version of series compressors with CO2 for bus air conditioning for pressures up to 150 bars.