Influence of temperature fluctuations on the operational behaviour of adsorption chillers.
Influencia de las fluctuaciones de temperatura en el comportamiento operativo de los enfriadores de adsorción.
Author(s) : SCHICKTANZ M.
Type of article: Article
Summary
Adsorption chillers are subject to fast temperature changes at the outlets of the hydraulic circuits. Depending on the peripherals the changes at the outlets lead to fluctuating temperatures at the inlets. This study reveals the influences of fast temperature fluctuations at the inlets to the operational behaviour of an adsorption chiller, especially on cooling power and COP. A transient model has been used for this investigation. Two different operation concepts are analyzed: 1) adsorption chillers with fixed cycle length; and 2) adsorption chillers with variable cycle length but a given set point for the mean chilled water outlet temperature. The focus is on the appearance of a temperature fluctuation at different times in the cycle. It turns out that the influence is little when dealing with fixed cycle lengths but fluctuations may trigger premature cycle termination when a controller is involved.
Available documents
Format PDF
Pages: 3-8 (5 p.)
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Influencia de las fluctuaciones de temperatura en el comportamiento operativo de los enfriadores de adsorción.
- Record ID : 30004358
- Languages: Spanish
- Source: Frío Calor Aire acondicionado - vol. 40 - n. 448
- Publication date: 2012/06
Links
- See translations: Influence of temperature fluctuations on the operational behaviour of adsorption chillers.
See other articles in this issue (3)
See the source
Indexing
-
Themes:
Chillers;
Absorption and adsorption systems - Keywords: Operation; Temperature; Adsorption system; Fluctuation; Water circuit
-
Influence of temperature fluctuations on the op...
- Author(s) : SCHICKTANZ M.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Investigation and comparison of two configurati...
- Author(s) : HELLMAN H. M., POHL J. P., GROSSMAN G.
- Date : 1996/09/03
- Languages : English
- Source: Applications for Natural Refrigerants
- Formats : PDF
View record
-
Dynamic modelling of a liquid absorption system.
- Author(s) : WILLERS E., GROLL M., KULICK C., et al.
- Date : 1999/03/24
- Languages : English
- Source: Proceedings of the International Sorption Heat Pump Conference.
View record
-
Thermodynamic modelling of an ammonia-water abs...
- Author(s) : CHUA H. T., TOH H. K., NG K. C.
- Date : 2002/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 25 - n. 7
- Formats : PDF
View record
-
Economic assessment of low firing temperature a...
- Author(s) : GOODHEART K. A., KLEIN S. A., SCHULTZ K.
- Date : 2002/01/12
- Languages : English
- Source: ASHRAE Transactions. 2002 Winter Meeting, Atlantic City, New Jersey. Volume 108, part 1 + CD-ROM.
View record