IIR document

Internal energy flow analysis within a single effect sorption heat pump.

Author(s) : SPINNER B., SORIN M., STITOU D.

Type of article: Article, IJR article

Summary

The knowledge of the characteristics of unused, excess and untapped exergy allows a thorough analysis of internal energy flows distribution within a sorption heat pump. It can be applied to any system based on gas-liquid absorption, adsorption or solid-gas reaction as well as to any process based on the internal recycling of the energy flux. It can also be applied for the case of a simple effect ideal machine, in particular in the definition of processes where the COP is larger than 2: the levels at which the initial exergy is downgraded on the one hand, as well as, the upgraded excess exergy produced on the over allows the designer to make a judicious choice of a system.

Available documents

Format PDF

Pages: 185-191

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Internal energy flow analysis within a single effect sorption heat pump.
  • Record ID : 2001-2026
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 24 - n. 2
  • Publication date: 2001/03

Links


See other articles in this issue (7)
See the source

Indexing