Summary
A novel cryogenic heat transfer system, which combines natural circulation cooling (NCC) and two-phase closed thermosiphon (TPCT) together has been proposed. Experimental investigations have proved that the coupling system (NCC + TPCT) has better cooling performance than either single NCC or single TPCT. Theoretical investigations on the steady-state heat transfer performance of single NCC and single TPCT have been performed. In this paper, a mathematic model was developed for the coupling system. The effects of NCC and TPCT on the cooling performance of the coupling system were determined. The calculated cooling temperatures agreed well with the experimental data.
Details
- Original title: Investigations on a cryogenic heat transfer unit combining natural circulation cooling and two-phase closed thermosiphon.
- Record ID : 2008-1931
- Languages: English
- Source: Cryogenics and refrigeration. Proceedings of ICCR'2008.
- Publication date: 2008/04/05
Links
See other articles from the proceedings (170)
See the conference proceedings
Indexing
-
Investigation of a closed two-phase nitrogen th...
- Author(s) : NAKANO A., SHIRAISHI M., NISHIO M., MURAKAMI M.
- Date : 1998/01
- Languages : Japanese
- Source: Cryogenics/ Cryog. Eng. - vol. 33 - n. 1
View record
-
Investigation of the effects of three key param...
- Author(s) : MO Q., LIANG J. T., CAI J. H.
- Date : 2007/04
- Languages : English
- Source: Cryogenics - vol. 47 - n. 4
View record
-
TWO-PHASE TRANSFER LIQUID NITROGEN COOLER FOR R...
- Author(s) : CHEN Y. C., LI Y. S.
- Date : 1983/12
- Languages : Chinese
- Source: J. chin. Assoc. Refrig. - n. 4
View record
-
UNSTEADY STATE HEAT TRANSFER IN SUPERINSULATED ...
- Author(s) : ARUNACHALAM S.
- Date : 1983
- Languages : English
- Source: Indian J. Cryog. - vol. 8 - n. 2
View record
-
HEAT TRANSFER AND TEMPERATURE PROFILE STUDIES I...
- Author(s) : ARUNACHALAM S.
- Date : 1983
- Languages : English
- Source: Indian J. Cryog. - vol. 8 - n. 2
View record