MEASUREMENTS OF THE TRANSIENT BEHAVIOUR OF A CAPILLARY STRUCTURE UNDER HEAVY THERMAL LOADING.

Author(s) : COLWELL G. T., CHANG W. S.

Type of article: Article

Summary

THE TRANSIENT OPERATING CHARACTERISTICS OF A SLAB TYPE CAPILLARY STRUCTURE IN A R11 HEAT PIPE HAVE BEEN STUDIED UNDER CONDITIONS WHICH CAUSE PARTIAL OR COMPLETE DRYING AND REWETTING TO OCCUR. DETAILED CHANGES WITH TIME IN INTERNAL LIQUID AND VAPOR TEMPERATURE DISTRIBUTIONS, INTERNAL PRESSURE, AND HEAT TRANSPORT CAPABILITY ARE PRESENTED. IT WAS FOUND THAT THE DEVICE WILL, UNDER SOME CONDITIONS, APPROACH STEADY OPERATION WITH A PORTION OF THE CAPILLARY STRUCTURE DRIED AND THAT REWETTING CAN BE QUICKLY ACCOMPLISHED. HOWEVER, WHEN THE ENTIRE STRUCTURE IS DRIED, REWETTING IS MUCH MORE DIFFICULT TO ACCOMPLISH.

Details

  • Original title: MEASUREMENTS OF THE TRANSIENT BEHAVIOUR OF A CAPILLARY STRUCTURE UNDER HEAVY THERMAL LOADING.
  • Record ID : 1985-0120
  • Languages: English
  • Source: International Journal of Heat and Mass Transfer - vol. 27 - n. 4
  • Publication date: 1984/04

Links


See other articles in this issue (4)
See the source

Indexing