IIR document

Modelling the forced-air cooling process of fresh strawberry packages. 1. Numerical model.

Author(s) : FERRUA M. J., SINGH R. P.

Type of article: Article, IJR article

Summary

A numerical analysis of the forced-air cooling process of retail packages of strawberries was performed by solving the conservation equations of mass, momentum and energy within the system. The results showed that the heterogeneity of the cooling process is largely influenced by the structure and design of the packaging system (individual clamshell packages and trays). On average 75 plus or minus 2% of the total airflow forced through the system bypassed the clamshells, and 46 plus or minus 5% of the flow rate forced through clamshells bypassed the strawberries. After 1 h of cooling, the average-fruit-temperature per clamshell ranged from 2.4 to 8.3°C between the first and last clamshells along the main flow direction. Within these clamshells, the maximum differences in the volume-average temperature of individual fruits reached 3.5 and 5.1°C, respectively. The results show the potential use of this numerical approach as a design tool to optimize the forced-air cooling process of horticultural products. See also this Bulletin, references 2009-0683 and 0684.

Available documents

Format PDF

Pages: 335-348

Available

  • Public price

    20 €

  • Member price*

    Free

* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).

Details

  • Original title: Modelling the forced-air cooling process of fresh strawberry packages. 1. Numerical model.
  • Record ID : 2009-0682
  • Languages: English
  • Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 32 - n. 2
  • Publication date: 2009/03

Links