Modifying a Joule-Thomson refrigerating system.
Modifizierung einer Gemisch-Joule-Thomson-Kältemaschine.
Author(s) : ALEXEEV A., HABERSTROH C., PELLE T., et al.
Summary
The proposals are made for improving the systems: 1) preliminary cooling through the oil-containing flow taken out by the liquid separator; 2) use of supplemental separation; 3) preliminary cooling with a separate system. Research was done on the effects of these modifications on the refrigerating system's specifications. It was found that simple alterations can improve efficiency and reliability considerably.
Details
- Original title: Modifizierung einer Gemisch-Joule-Thomson-Kältemaschine.
- Record ID : 2000-0567
- Languages: German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
- Publication date: 1998/11/18
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (67)
See the conference proceedings
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Joule-Thomson; Performance; Cryocooler; Cryogenics
-
POSSIBILITES DE LA REFRIGERATION DE TRES FAIBLE...
- Author(s) : FAURE A.
- Date : 1984/03
- Languages : French
- Source: Vide Couches minces - suppl. n. 221
View record
-
ADVANCES IN JOULE-THOMSON (JT) COOLING.
- Author(s) : LITTLE W. A.
- Date : 1990
- Languages : English
- Source: Adv. cryog. Eng. - vol. 35 B
View record
-
MEASUREMENT OF FRICTION FACTORS FOR THE FLOW OF...
- Author(s) : WU PEIYI, LITTLE W. A.
- Date : 1983
- Languages : English
- Source: Cryogenics - vol. 23 - n. 5
View record
-
Improving the performance of small Joule-Thomso...
- Author(s) : YU J.
- Date : 2008/09
- Languages : English
- Source: Cryogenics - vol. 48 - n. 9-10
View record
-
A strategy to optimize the charge amount of the...
- Author(s) : PANG W., LIU J., XU X.
- Date : 2016/09
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 69
- Formats : PDF