Summary
Underground thermal imbalance is a common problem in ground-coupled heat pump (GCHP) system operated in cooling-dominated district, which will cause the average underground soil temperature to rise, and inevitably deteriorate the operation performance of GCHP system. In this paper, a two-dimensional heat transfer model with groundwater advection was developed for modeling the heat transfer of underground GHE array. The influences of underground thermal imbalance rate, soil type, borehole layout and groundwater advection on the underground soil temperature distribution were analyzed. The results indicate that the soil temperature increase with the increase of the ratio of annual heat released into the ground to that extracted from the ground, and thus the underground thermal imbalance becomes worse. The better the soil thermal conductivity and diffusivity are, the faster the soil heat diffusion is, and thus the underground heat buildup can be alleviated. At the same time, the underground thermal imbalance can be controlled or eliminated by decreasing the intensive degree of borehole layout through increasing the borehole spacing or using strip type and block layout. Additionally, the underground heat buildup can be efficiently removed by the groundwater advection.
Details
- Original title: Numerical investigation on the underground thermal imbalance of ground-coupled heat pump operated in cooling-dominated district.
- Record ID : 30011406
- Languages: English
- Source: Applied Thermal Engineering - vol. 58 - n. 1-2
- Publication date: 2013/09
- DOI: http://dx.doi.org/10.1016/j.applthermaleng.2013.04.061
Links
See other articles in this issue (6)
See the source
Indexing
-
Themes:
Heat pumps techniques;
Heat transfer - Keywords: Temperature variation; Heat transfer; Ground; Heat pump; Model
-
Numerical evaluation on the effects of soil fre...
- Author(s) : YANGA W., KONGA L., CHEN Y.
- Date : 2015/01/22
- Languages : English
- Source: Applied Thermal Engineering - vol. 75
View record
-
Long-term ground-temperature changes in geo-exc...
- Author(s) : BERNIER M. A., CHAHLA A., PINEL P.
- Date : 2008/06/21
- Languages : English
- Source: ASHRAE Transactions. 2008 Annual Meeting, Salt Lake City, UT. Volume 114, part 2 + CD-ROM.
View record
-
Heat transfer in horizontal ground heat exchang...
- Author(s) : KUPIEC K., LARWA B., GWADERA M.
- Date : 2015/01/22
- Languages : English
- Source: Applied Thermal Engineering - vol. 75
View record
-
A model for annual simulation of standing colum...
- Author(s) : DENG Z., REES S. J., SPITLER J. D.
- Date : 2005/10
- Languages : English
- Source: HVAC&R Research - vol. 11 - n. 4
View record
-
Heat transfer of ground heat exchanger for GSHP...
- Author(s) : YUAN Y., LEI B., YU N., et al.
- Date : 2009/06
- Languages : Chinese
- Source: HV & AC - vol. 39 - n. 226
- Formats : PDF
View record