Numerical simulation of capillary-tube expansion devices behaviour with pure and mixed refrigerants considering the metastable region. 2. Experimental validation and parametric studies.

Author(s) : GARCÍA-VALLADARES O., PÉREZ-SEGARRA C. D., OLIVA A.

Type of article: Article

Summary

A detailed one-dimensional steady and transient numerical simulation has been developed and presented in part 1 of this article (see this Bulletin, reference 2003 - 1240). The accuracy of the detailed simulation model is demonstrated in this part by comparison with experimental data from the technical literature. Numerical results and parametric studies for concentric capillary tube-suction line heat exchangers are also presented.

Details

  • Original title: Numerical simulation of capillary-tube expansion devices behaviour with pure and mixed refrigerants considering the metastable region. 2. Experimental validation and parametric studies.
  • Record ID : 2003-1249
  • Languages: English
  • Source: Applied Thermal Engineering - vol. 22 - n. 4
  • Publication date: 2002/03