IIR document
Numerical simulation of non-adiabatic capillary tubes considering metastable region. 2. Experimental validation.
Author(s) : GARCÍA-VALLADARES O.
Type of article: Article, IJR article
Summary
A detailed one-dimensional steady and transient numerical simulation of the thermal and fluid-dynamic behavior of capillary tube-suction line heat exchangers considering metastable region and separated flow has been developed in part I of this paper (see this Bulletin, reference 2007-1083). The developed numerical model allows analysis of aspects such as geometry, type of fluid, critical or non-critical flow conditions and metastable region. The accuracy of the detailed simulation model is demonstrated in this part (of the paper by comparing simulation results with a wide range of steady state experimental data from the technical literature, which include the refrigerant mass flow rate, outlet suction line temperature, and temperature profile along concentric and lateral capillary tube-suction line heat exchangers. Of the 196 data points evaluated for mass flow rate, 96.4% are within an error of plus or minus 15%, 81.1% are within plus or minus 10% with a mean deviation of plus or minus 6.3%. Of the 143 data points evaluated for outlet suction line temperature 89.5% are within an error of plus or minus 2°C, with a mean deviation of plus or minus 0.98°C. The numerical results obtained are used to understand the refrigerant flow behavior inside non-adiabatic capillary tubes. Some divergence problems in the numerical solution process is found to be the discontinuity in non-adiabatic capillary tube flow characteristics caused by re-condensation of the refrigerant within the heat exchanger zone; this aspect needs special attention while modeling the non-adiabatic capillary tube flow. Other important parameter to be evaluated experimentally with special care is the capillary tube internal diameter due to its strong influence on the refrigerant flow results (results of any study based on the nominal diameter are to be used with caution).
Available documents
Format PDF
Pages: 654-663
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Numerical simulation of non-adiabatic capillary tubes considering metastable region. 2. Experimental validation.
- Record ID : 2007-1084
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 4
- Publication date: 2007/06
Links
See other articles in this issue (15)
See the source
Indexing
-
Numerical simulation of non-adiabatic capillary...
- Author(s) : GARCÍA-VALLADARES O.
- Date : 2007/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 30 - n. 4
- Formats : PDF
View record
-
Numerical investigation of HFC-134a flow throug...
- Author(s) : KALEEM KHAN M., KUMAR R., KUMAR SAHOO P.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
A new method of modelling HFC-134a flow through...
- Author(s) : WANG L., ZHANG G. Q., LIU L., et al.
- Date : 2003/04/22
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR 2003.
View record
-
Mass flow rate correlation for two-phase flow o...
- Author(s) : VINS V., VACEK V.
- Date : 2009/10
- Languages : English
- Source: Applied Thermal Engineering - vol. 29 - n. 14-15
View record
-
Modelling of critical two-phase flow in capilla...
- Author(s) : BUTRYMOWICZ D., KARWACKI J.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record