Summary
In this study. an ammonia refrigeration room was selected as a typical scenario. Computational fluid dynamics (CFD) was applied to study the rules of the ammonia-Ieakage diffusion. The ammonia-Ieakage diffusion in a refrigeration room with up-down ventilation
and without ventilation was numerically simulated using the Fluent CFD software package. The ammonia concentrations in the longitudinal profile and the cross-section of the refrigeration room were analyzed at different times after the ammonia leakage. The numerical simulation results show that the ammonia concentration increases with height in the refrigeration room. and a lower fresh-air inlet can quickly decrease the ammonia concentration. Based on the above results. it is proposed that an ammonia-gas alarm should be installed near the ceiling to detect the leakage. and an emergency exhaust inlet should be installed near the floor to decrease the ammonia concentration.
Available documents
Format PDF
Pages: 12-19
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30024003
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 38 - n. 6
- Publication date: 2017/12
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2017.06.012
Links
See other articles in this issue (3)
See the source
Indexing
-
An ultra-low ammonia charge system for industri...
- Author(s) : SHANMUGAM S. K. G., MITAL M.
- Date : 2019/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 107
- Formats : PDF
View record
-
PROTECTING FOOD PRODUCTS IN COLD ROOMS AGAINST ...
- Author(s) : FEDASZ A., MAGNOWSKA M.
- Date : 1988
- Languages : Polish
- Source: Chlodnictwo - vol. 23 - n. 11
View record
-
SOME SERIOUS SAFETY PROBLEMS USING AMMONIA. OPE...
- Author(s) : BOJANOWSKI W.
- Date : 1985
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 8 - n. 1
- Formats : PDF
View record
-
ANTEROOMS IN COLD STORES.
- Author(s) : NICCOLAI G.
- Date : 1986
- Languages : Italian
- Source: Industria italiana del Freddo - vol. 40 - n. 1
View record
-
Une chambre froide à température supérieure à z...
- Author(s) : ROGER R.
- Date : 2006/01
- Languages : French
- Source: La revue pratique du froid et du conditionnement d'air - n. 942
View record