IIR document
Optimal design and analysis of mechanical draft cooling tower using improved Jaya algorithm.
Author(s) : RAO R. V, MORE K. C.
Type of article: Article, IJR article, Case study
Summary
A cooling tower is an imperative component of industrial plants. The minimization of energy related expenses is critical for conservation of resources and energy savings. Hence, the present study explores the use of an improved Jaya algorithm called self-adaptive Jaya algorithm for optimal design of cooling tower from economic facets. In this work, six different examples are considered in the design optimization of mechanical draft cooling tower. Various researchers have attempted the same mathematical models by using different methods like Merkel method, Poppe method and artificial bee colony (ABC) algorithm. The results achieved by using the proposed self-adaptive Jaya algorithm are compared with the results achieved by using the Merkel method, Poppe method, ABC algorithm and basic Jaya algorithm. The proposed self-adaptive Jaya algorithm determines the population size automatically and the user need not tune the population size. The proposed self-adaptive Jaya algorithm is proved better as compared to the other optimization methods with respect to achieving the optimal value of the objective function at less computational effort.
Available documents
Format PDF
Pages: 312-324
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Optimal design and analysis of mechanical draft cooling tower using improved Jaya algorithm.
- Record ID : 30022311
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Publication date: 2017/10
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2017.06.024
Links
See other articles in this issue (42)
See the source
Indexing
- Themes: Evaporators, condensers and other heat exchangers
- Keywords: Cooling tower; Design; Optimization; Case study; Energy efficiency; Cost
-
Special reports: coolers, condensers and heat e...
- Date : 2004/05
- Languages : English
- Source: S. afr. Inst. Refrig. Air Cond. - vol. 106 - n. 1274
View record
-
Application of cooling tower technology to a di...
- Author(s) : HE B., ZHANG Z., LI H., et al.
- Date : 2014/07
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 292
- Formats : PDF
View record
-
How fan noise reduction affects cost.
- Author(s) : GIAMMARUTI R.
- Date : 2008/11
- Languages : English
- Source: Build. Serv. J. - vol. 87 - n. 11
View record
-
Presentation of an integrated cooling system fo...
- Author(s) : PENG W., SADAGHIANI O. M.
- Date : 2021/11
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 131
- Formats : PDF
View record
-
Ground-source water loop heat pump system design.
- Author(s) : XU X.
- Date : 2013/01
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 273
- Formats : PDF
View record