Summary
Linear compressor is a promising alternative for commercial refrigerator using R290. In this paper, a design program of linear compressor is set up. The leakage mass flow rate is modeled based on small hole leakage principle. The errors of the model are within 10%. The cooling performance of linear compressor with different piston diameter for commercial referigerator using R290 is analyzed. As the linear compressor is set to have the same swept volume, small piston diameter is beneficial to the COP improvement, but has a few decrease of cooling capacity. As the linear compressor is set to have the same cooling capacity by adjusting power frequency, COP of the linear compressor with piston diameter of 28?mm and 30?mm gets a little decrease because the power frequency deviates from the inherent frequency. The optimal piston diameter of 12 CC swept volume for the commercial refrigeration is suggested to be from 30?mm to 32?mm.
Available documents
Format PDF
Pages: 55-63
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance analysis of linear compressor using R290 for commercial refrigerator.
- Record ID : 30027196
- Languages: English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 109
- Publication date: 2020/01
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2019.10.002
Links
See other articles in this issue (20)
See the source
Indexing
-
Themes:
Compressors;
Hydrocarbons;
Supermarkets, display cabinets - Keywords: Commercial application; Linear compressor; Display cabinet; R290; Propane; Modelling; COP
-
Propane as R22-replacement in commercial applia...
- Author(s) : JÜRGENSEN H.
- Date : 2008/11/13
- Languages : English
- Source: Danfoss Compress. - 4 p.; fig.; tabl.
View record
-
Energy saving design of the vertical refrigerat...
- Author(s) : WEI H., CHEN K.
- Date : 2012/12
- Languages : Chinese
- Source: Refrigeration - vol. 31 - n. 4
View record
-
Enjeux environnementaux des installations frigo...
- Author(s) : RIVOALLON R.
- Date : 2013/09
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 103 - n. 1136
View record
-
Two-fluid model for air supply opening of air c...
- Author(s) : YU K., DING G., CHEN T.
- Date : 2007/06
- Languages : Chinese
- Source: Journal of Refrigeration - vol. 28 - n. 3
- Formats : PDF
View record
-
Badania mebli chlodniczych.
- Author(s) : STEINDEL M., BEDNARCZYK L.
- Date : 2006/11
- Languages : Polish
- Source: Chlodnictwo - vol. 41 - n. 11
View record