Performance evaluation of a passive chilled beam system and comparison with a conventional air system.
Number: pap. 3231
Author(s) : KIM J., BRAUN J. E., TZEMPELIKOS A., et al.
Summary
This study compares the performance of a system employing passive chilled beams with a conventional air system in a typical open plan office setting. Both energy efficiency and thermal comfort are taken into account as performance indicators. A typical single duct variable air volume system, widely used in large office buildings, was considered as a conventional system; a combination of the air system and passive chilled beams was considered as a typical passive chilled beam system. Measurements from full-scale experiments conducted in open plan offices (Living Labs of the Center for High Performance Buildings at Purdue) are used to develop a data-driven passive chilled beam model that can predict the total cooling capacity as well as surface temperatures under different operating conditions. In simulating the performance of the two systems, the same operative temperature was used in order to have a fair comparison. Additionally, the effect of radiation cooling of the passive chilled beam was investigated. The overall results showed about maximum 10-21% total electrical energy savings (5-23% reduction in chiller and 55% reduction in supply fan electrical energy) and thermal comfort improvement of 0.3-0.4 on a PMVscale (12-15% on a PPD scale) associated with the passive chilled beam system, depending on the system configuration. The radiation cooling of the passive chilled beam is not significant, since the effective surface area for radiant exchange with the room is much less than the surface area for convective heat transfer and temperature differences are relatively low.
Available documents
Format PDF
Pages: 11 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance evaluation of a passive chilled beam system and comparison with a conventional air system.
- Record ID : 30019305
- Languages: English
- Source: 2016 Purdue Conferences. 4th International High Performance Buildings Conference at Purdue.
- Publication date: 2016/07/11
Links
See other articles from the proceedings (77)
See the conference proceedings
Indexing
- Themes: Comfort air conditioning
- Keywords: Office; Comparison; Performance; Chilled beam; Energy efficiency; Thermal comfort
-
Caracterización térmica y evaluación de diversa...
- Author(s) : GONZÁLEZ ESPÍN J. L., DOMÍNGUEZ MUÑOZ F., CEJUDO LÓPEZ J. M., et al.
- Date : 2018/06/19
- Languages : Spanish
- Source: CYTEF 2018. IX Congreso Ibérico y VII Congreso Iberoamericano de Ciencias y Técnicas del Frío, Valencia, España, 19-21 junio 2018.
- Formats : PDF
View record
-
VAV reheat versus active chilled beams & DOAS.
- Author(s) : STEIN J., TAYLOR S. T.
- Date : 2013/05
- Languages : English
- Source: ASHRAE Journal - vol. 55 - n. 5
View record
-
Efficiency and flexibility. A new cooling syste...
- Author(s) : BUSTAFFA L., CARLI M. de, GUIDI V., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record
-
Taking flexibility into account in designing be...
- Author(s) : KOSONEN R., VIRTA M., OY H.
- Date : 2008/05
- Languages : English
- Source: IRHACE J. - vol. 20 - n. 3
View record
-
Two-pipe chilled beam system for both cooling a...
- Author(s) : AFSHARI A., NOROUZI R. G., HULTMARK G., et al.
- Date : 2013/06/16
- Languages : English
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
View record