Recommended by the IIR / IIR document
Performance evaluation of solar-activated integrated double-stage water desalination and air conditioning plant.
Author(s) : SAXENA A., TANGELLAPALLI S.
Type of article: IJR article
Summary
The condenser's rejected heat in a vapour compression refrigeration system when thrown into the surrounding air results in its thermal pollution and gets wasted, while it has the potential to be recovered. Another major targeted concern is freshwater scarcity which is faced by the population in many areas. Addressing these difficulties, a double-stage integrated humidification-dehumidification and air conditioning system that recovers the condenser's waste heat and is assembled in a novel duct architecture is proposed. The obtained results of the developed model are established using the experimental data. The analysis explores the outcomes of the integrated system and investigates the influences of saline water temperature, humidifier efficiency, ambient temperature, and relative humidity on the output and performance metrics. The system provides air conditioning of 31.410 kJ and desalination of 65.020 mL from a unit volume of air using 0.661 kW of power and mitigates the environmental impact of existing technology. The coefficient of energy performance, cooling performance, gained output ratio, and exergy efficiency at the specified working situations are 0.958, 1.320, 6.809, and 2.701 %, respectively. A litre of freshwater costs $ 0.0068486.
Available documents
Format PDF
Pages: 119-128
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Performance evaluation of solar-activated integrated double-stage water desalination and air conditioning plant.
- Record ID : 30032251
- Languages: English
- Subject: Technology
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 160
- Publication date: 2024/04
- DOI: http://dx.doi.org/10.1016/j.ijrefrig.2024.02.001
Links
See other articles in this issue (33)
See the source
-
Independent air dehumidification with membrane-...
- Author(s) : LIANG C. H., ZHANG L. Z., PEI L. X.
- Date : 2010/03
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 2
- Formats : PDF
View record
-
Minimierung der latenten Kühlleistung durch ein...
- Author(s) : KAUP C.
- Date : 2003/12
- Languages : German
- Source: KI Luft Kältetech. - vol. 39 - n. 12
View record
-
Application of evaporative condensation air con...
- Author(s) : TAN H., QU G. L., HUANG W., et al.
- Date : 2012/06
- Languages : Chinese
- Source: HV & AC - vol. 42 - n. 264
- Formats : PDF
View record
-
Application of pump-assisted separate heat pipe...
- Author(s) : GUO Z. J., SHAO J., LI X. H., et al.
- Date : 2016/04/05
- Languages : English
- Source: Applied Thermal Engineering - vol. 98
View record
-
Outdoor air-handling system of liquid desiccant...
- Author(s) : WANG J., LI Z., YUAN Y., et al.
- Date : 2013/01
- Languages : Chinese
- Source: HV & AC - vol. 43 - n. 273
- Formats : PDF
View record