Phase controls for pulse-tube refrigerator of the third generation.

[In Japanese. / En japonais.]

Author(s) : TOMINAGA A.

Type of article: Article

Summary

Discussed are methods of controlling phase difference between oscillations of pressure and displacement at the hot end of a pulse-tube. Electric analogs of fluid mechanical system are discussed in the beginning and fluid mechanical components corresponding to capacitance, inductance and resistance in electric circuits are clarified. Then the phase difference is discussed in terms of equivalent cicuit-network.

Details

  • Original title: [In Japanese. / En japonais.]
  • Record ID : 1993-0006
  • Languages: Japanese
  • Source: Cryogenics/ Cryog. Eng. - vol. 27 - n. 2
  • Publication date: 1992
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (6)
See the source